APOLLO 1120F/1120 1200VA Offline UPS
Key Features
- Model: 1120F
- Load Capacity: 1200VA
- Transfer Time: 2ms typical; 5ms maximum
- Waveform: PWM Simulated Sine wave
- 2 x Lead-Acid maintenance-free battery
| Main Feature | ||
| Capacity | 1200VA | |
| Frequency (Battery Mode) | 60Hz | |
| Noise Level | EMI/RFI full time suppression | |
| Battery | 2 PCS Lead-Acid maintenance-free | |
| Alarm | On Battery, Battery Low and Overload | |
| Indications | AC Normal: Green LED Steadily; Backup: Yellow LED intermittently | |
| Input Features | ||
| Frequency | 50Hz or 60Hz | |
| Voltage Range | 100/110/120/220/230/240VAC Nominal -25%+25% | |
| Output Features | ||
| Backup Time | 10-30 minutes depending on load connected | |
| Type of Wave | PWM Simulated Sine wave | |
| Transfer Time | 2ms typical; 5ms maximum | |
| Manufacture Warranty | ||
| Warranty | 1 Year Under the following conditions, the warranty would not be provided: • UPS burning due to thunder, abnormal overload, insect entrance and others. • If ambient temperature should not be maintained at 20 to 26 degrees Celsius with proper dehumidification. (24/7) • If the product is placed in a dusty and damp place. • In the absence of Generator connectivity Without proper battery charge, the warranty will be void. • Battery swelling and overcharging due to the wrong system voltage setting of the UPS. | |
APOLLO 1120F/1120 1200VA Offline UPS
The APOLLO 1120F 1200VA Offline UPS offers a capacity of 1200VA with a double battery with 12V 7AH. This Offline UPS has an input voltage of 100/110/120/220/230/240VAC Nominal -25%+25% and an output voltage of 240Vac with a frequency of 60Hz. The UPS has a transfer rate of 2 milliseconds and is also equipped with a built-in stabilizer. The APOLLO 1120F Offline UPS weighs in at 4 Kg.
The APOLLO 1120F / 1120 1200VA Offline UPS comes with a 1 Year Manufacturer Warranty, ensuring reliable power backup and protection for your electronic devices. The warranty covers manufacturing defects under normal operating conditions.
During the warranty period, the product may be repaired or replaced according to the manufacturer's service policy.
• UPS damage caused by thunder, lightning, abnormal overload, insect entry, or electrical surge
• If the ambient temperature is not maintained between 20°C to 26°C with proper dehumidification (24/7)
• If the UPS is installed in dusty, humid, or damp environments
• Lack of generator connectivity or improper battery charging conditions
• Battery swelling or overcharging due to incorrect UPS voltage settings
Proper installation and maintenance are recommended to ensure long term performance and warranty coverage.