Apollo 2B15K-L 15KVA Long Backup Online UPS

Key Features

  • Model: 2B15K-L
  • Capacity: 15KVA / 13.5KW
  • Input Voltage: 380/400/415V AC
  • Topology: Online
  • Short Circuit, Overload and Overcharge Protection

Specification

Main Feature
Capacity15KVA
Display TypeLCD
Load Capacity13.5 KW
Input Voltage380/400/415Vac (380-25% 415+20%), (3Ph+N+PE)
Noise Level<60dB
BatteryBattery voltage: 384Vdc
OthersDisplay
LED: Input, Inverter, Bypass, Battery, Output, Status
LCD: I/O voltage, frequency, power factor, battery voltage, current, battery status, load percentage, UPS status, history record
Operating frequency range: 50/60Hz (±5Hz)
Output frequency: 50/60Hz (± 0.05%)
Power: >0.9(with filter)
Interface: Dry contact, RS232, RS485, SNMP card (Optional)
Harmonic distortion (THD) <3% (linear load)
Crest factor 3:1 (Max.)
Rated frequency: 50/60Hz
Transfer time: Oms (Line mode ↔ Battery mode)
Harmonic filter, SNMP adapter, LBS cables, battery temperature sensor,
Bypass current-sharing inductor
Special Features:
Voltage protection range: Upper limit: +20% (+10%, +15%, +20% adjustable)
Lower limit: -40%, -20%, -30%, -40% adjustable)
Frequency protection range: ± 10% (±2.5%, ±5%, ±10%, ±20% adjustable)
Input Features
Voltage Range380/400/415Vac (380-25% 415+20%), (3Ph+N+PE)
Output Features
Voltage Range200/220/230Vac (± 1%)
Transfer Time0 ms (Line mode ↔ Battery mode)
Physical Specification
Dimension570 x 800 x 1195mm
Weight217kg

Manufacture Warranty
Warranty1 Year (Box Mandatory While Claiming)
Under the following conditions, the warranty would not be provided:
• UPS burning due to thunder, abnormal overload, insect entrance and others.
• If ambient temperature should not be maintained at 20 to 26 degrees Celsius with proper dehumidification. (24/7)
• If the product is placed in a dusty and damp place.
• In the absence of Generator connectivity Without proper battery charge, the warranty will be void.
• Battery swelling and overcharging due to the wrong system voltage setting of the UPS.

Product Details

Apollo 2B15K-L 15KVA Online UPS is a high performance long backup power solution designed for mission critical applications that require continuous, stable, and efficient electricity. With a rated capacity of 15KVA (13.5KW), it delivers reliable backup power for data centers, industrial facilities, telecom systems, hospitals, and other sensitive infrastructures.

Built with advanced online double conversion technology, this UPS ensures complete isolation from mains power disturbances and delivers clean, regulated power at all times. It operates with a three phase input voltage range of 380/400/415Vac (3Ph+N+PE) with wide tolerance support, ensuring stable performance even in challenging electrical environments.

The system provides a precise output voltage of 200/220/230Vac (±1%) with ultra stable frequency control at 50/60Hz (±0.05%). With zero transfer time (0ms) between line and battery mode, it guarantees uninterrupted operation for critical loads without any downtime.

Offering high efficiency of over 89%, low harmonic distortion (<3% for linear loads), and a 3:1 crest factor, this UPS is capable of handling both sensitive and high inrush industrial equipment with excellent stability and performance.

The 384VDC battery system ensures long duration backup capability, making it ideal for extended power outages. Intelligent battery management helps optimize charging performance and extends overall battery life.

For monitoring and control, the UPS features an advanced LCD and LED display system that provides real time data including input/output voltage, frequency, power factor, load percentage, battery status, and system history logs. It supports RS232, RS485, and optional SNMP communication for remote monitoring and integration into network systems.

Built in protection features include adjustable voltage and frequency protection ranges, overload protection, short circuit protection, and thermal management systems, ensuring maximum safety and reliability under all operating conditions.

With a robust industrial design (570 × 800 × 1195mm, 217kg), the Apollo 2B15K-L 15KVA Online UPS is engineered for durability, high performance, and continuous uptime in demanding environments. It fully complies with IEC/EN safety standards, ensuring dependable long term operation.

Optional accessories such as harmonic filters, SNMP adapter, battery temperature sensor, and bypass current sharing inductor further enhance system flexibility and performance, making it a complete long backup UPS solution for critical operations.

Warranty Policy

  • 1 Year Warranty (Box mandatory during claim)
  • Covers manufacturing defects under normal operating conditions

Warranty will not apply under the following conditions:

  • Damage caused by lightning, thunder, electrical surge, or natural disaster
  • Overload, short circuit, or improper installation/use
  • Insect or pest damage inside the unit
  • Use in dusty, humid, or poorly ventilated environments
  • Failure to maintain recommended temperature (20°C to 26°C with proper humidity control)
  • Improper generator connection or incorrect battery charging system
  • Battery swelling or damage due to incorrect system configuration
  • Unauthorized repair, modification, or physical damage

0.0

Average Rating

0.00% Recommended(1 of 3)
0%
0%
0%
0%
0%

Submit Your Review